Call us: 10am – 6pm ET

+1 888 540-2010
+1 416 833-3501

Call us: 10am – 6pm ET

+1 888 540-2010
+1 416 833-3501

Reassembling RAID 5 with a missing drive from image files

Imagine you have image files that are created from source RAID 5 drives. If one of RAID 5 drives was missing or heavily damaged, one image file is missing or incomplete, too. TaskForce uses RAID 5 redundancy to create a full image of the RAID even in such cases.

To reassemble a RAID from image files:

1. Click the RAID icon in the left-side Task menu
2. In the FILE subsection of the Select source devices slide-out panel click SELECT FILE tile
3. In the Select image file explorer find the directory with the images you want to use and select the files. Then click the Select button

Selecting RAID 5 image files

Selecting RAID 5 image files

4. Click Continue

Selecting RAID 5 image files

Selecting RAID 5 image files

5. Autodetection module starts running automatically to find a suitable RAID configuration. You know that there is an image file missing from the selection (it may have been lost or damaged), so click Add missing device button underneath the list of image files

Add missing RAID 5 drive

Add missing RAID 5 drive

6. Autodetection will recommence when a new image file or device is added. If the RAID is type 5, TaskForce will be able to identify the right configuration and reassemble the RAID by using the redundancy. When a possible configuration is found, click the Apply button.

Apply the found RAID configuration

Apply the found RAID configuration

The configuration application automatically changes the order of the drives/images, the detected RAID type, block size and order is applied automatically, too. In the bottom part of the screen, the found partitions are available for preview.

7. To proceed with imaging, click the Go to image button and follow the instruction in subsequent screens to select the target and adjust imaging settings.

Preview the found partitions and proceed to image

Preview the found partitions and proceed to image

During the imaging, TaskForce takes advantage of the redundancy to create an image of the RAID despite one of the devices is missing.

Imaging RAID 5 with a missing drive

Imaging RAID 5 with a missing drive

The imaging report clearly indicates which of the devices that make up the RAID array was missing. Other RAID parameters, such as type, block size and order are also clearly reflected in the report.

Imaging report clearly indicates the missing device in RAID 5

Imaging report clearly indicates the missing device in RAID 5